PURELAB FLEX 2 - BASIC UNIT, INCLUDES LC208 ONLY. (MAY REQUIRE LA652 PRESSURE REGULATOR)

SKU
SK-FLEX2-US

Description

PURELAB FLEX 2 - BASIC UNIT, INCLUDES LC208 ONLY. (MAY REQUIRE LA652 PRESSURE REGULATOR)

Conductivity

<1 µS/cm

Organics (TOC)

N/A

Temperature

15-25 °C

System Voltage

24V DC

Part Number

SK-FLEX2-US

Silica

<2 ppm

Organics (TOC)

<5 ppb

Footnotes

Bacteria - Specification subject to use with a POU (point of use) Biofilter. If Microfilter is used, then Bacteria level is <1 CFU/ml TOC - Specification dependant on feedwater Endotoxin - Specification subject to use with a Biofilter DNase/RNase - Specification subject to use with a Biofilter

RNase

0.002 ng/ml

Breite (mm)

2369

Bacteria

<0.1 CFU/ml (<1 CFU/10ml)

Brand Name Range

PURELAB

Carbon Dioxide

<0.1 ppm

Chloramine

< 0.05 ppm

Total Chlorine

< 0.05 ppm

Daily Usage (8hr day)

< 100 l/day

Applications

AAS (Atomic absorption spectrophotometry), Bacterial cell culture, Buffer and media preparation, Clinical biochemistry, Electrochemistry, Electrophoresis, Electrophysiology, ELISA (Enzyme linked immunoabsorbant assay), Endotoxin analysis, Flame-AAS, GC-MS, General chemistry, GF-AAS (Graphite Furnace - Atomic Absorption Spectrophotometry), Histology, HPLC, Hydroponics, IC (Ion chromatography), ICP-AES (Inductively Coupled Plasma - Atomic Emission Spectrometry), ICP-MS (Inductively Coupled Plasma - Mass Spectrometry), Immunocytochemistry, Mammalian and bacterial cell culture, Media preparation, Microbiological analysis, Molecular biology, Monoclonal antibody research, Plant growth cabinets, Plant tissue culture, Qualitative analyses, RIA (Radioimmunoassay), Sample dilution and reagent preparation, Solid phase extraction, Spectrophotometry, Stability chambers, TOC analysis, Trace metal detection, Ultra sonic bath, Ultra trace analysis, Water analysis

Depth (mm(inch))

374 (14.7)

Höhe (mm)

90035

Delivery Flow Rate

up to 2 l/min

Footnotes

Flexible Height - 900 to 1020 mm

DNase

<20 pg/ml

Inorganics

18.2 MΩ-cm

Installation Options

Bench, Wall

Mains Input

100-240V ac, 50-60 Hz

Max. Pressure

1.5 Bar

Min. Pressure

Flooded suction

Noise Level

<40 dBA

Drain (gravity fall with air gap)

None required

Endotoxins

<0.001 EU/ml

Footnotes

Feedwater Conductivity - If feedwater is in the range of 1 μS/cm - 30 μS/cm you will need a pre-conditioning kit. Endotoxin - Specification subject to use with a Biofilter DNase/RNase - Specification subject to use with a Biofilter

Feedwater Nature

Pre-treated (RO/SDI/Distilled)

Flow Rate

>2 l/min

Fouling Index

<1

Free Chlorine

<0.05 ppm

Ships within

4 weeks

Betriebs-Gewicht (kg)

1124

Shipping Depth

13

© 2022 Veolia Water Technologies. All Rights Reserved.